Edge Comfort

What we make

One PCM module family. Sized for your room.

We make and ship high-conductivity PCM modules. The online Studio sizes the bank and shows how it may change indoor temperatures. Furniture, fans, sensors and optional cooling stay yours or come from independent sellers.

We sell and ship

High-conductivity PCM modules.

Included online

Studio calculation model — no hub hardware.

You source separately

Sensors, furniture, fans, cooling equipment, delivery and installation.

Two Passive Edge PCM Cooling Module packages, 300 by 300 by 30 millimetres, on a wooden table
Modules ship flat — 300 × 300 × 30 mm T3 PCM modules for furniture builds.

Direct PCM enquiries

PCM modules across six language markets

Passive Edge PCM modules can be requested and ordered directly in all six website languages: English, German, French, Dutch, Chinese and Japanese.

EnglishDeutschFrançaisNederlands中文日本語

Delivery country, freight, taxes and commercial terms are confirmed in the written quotation.

Request a PCM module quote
Window bench with its slatted door open, revealing a bank of five stacked PCM cooling modules
The module bay: five PCM modules slide into a standard window bench, breathing through the slats.

PCM kits — what we ship

Kit

Starter Kit

PCM modules

3–4 × T3 modules (0.462–0.616 kWh)

Best For

Small bedroom or study up to ~10 m²

Positioning

Entry

Kit

Core Kit

PCM modules

5–8 × T3 modules (0.770–1.232 kWh)

Best For

12–20 m² bedroom or living room

Positioning

Most rooms

Kit

Max Kit

PCM modules

9–12 × T3 modules (1.386–1.848 kWh)

Best For

Large, hot or top-floor rooms up to ~28 m²

Positioning

High load

PCM temperature zones

Sleep Pack

around 22°C

Bedrooms and sleep comfort

Comfort Pack

around 24°C

Living spaces and daily comfort

Heatwave Buffer Pack

around 26°C

Higher passive recharge probability during heatwaves

Warm Climate Pack

around 28°C

Warm-climate buffering when nights do not reliably fall into the lower comfort SKUs

Hot Climate Pack

around 30°C

Hot-climate rooms with repeated warm nights and higher recharge temperatures

Extreme Heat Pack

around 32°C

Closed-window or extreme warm-night recharge scenarios where the highest phase point is appropriate

Compact recharge unit mounted under a shelf, blowing cool air over a stack of PCM cooling modules

Hybrid recharge

Tropical night? Top up off-peak.

When night air is not cool enough, a compact recharge unit — or the AC you already own — quietly refreezes the PCM modules during off-peak hours. The Studio model calculates a suggested recharge window; your own timer or control equipment operates the hardware.

See the full cycle
All-season

One platform. Every season.

The same high-conductivity module platform comes in six phase-change temperatures — 22 / 24 / 26 / 28 / 30 / 32°C. Swap the bank when the season turns.

Blue-lit airflow streaming through the PCM module bank of a window bench in summer

Summer

22–32°C

Night air — or off-peak AC — recharges the PCM modules. By day they absorb the room's heat and a quiet fan spreads the coolth.

Winter evening at home: PCM heat modules glowing warm amber behind the slats of a window bench

Winter

~32°C

Swap in higher-temperature PCM modules. A small fan heater or air-source heat pump charges them during off-peak hours; they release gentle, even warmth for hours after.

Because PCM charges and discharges at a nearly constant temperature, it clips the peaks and troughs of the day — the room holds a steady, comfortable band instead of swinging hot and cold. Your body feels the difference: steadier rooms mean deeper sleep and calmer days.

Parts library

Every part of the build — ours, yours or a partner's.

Open each part to see what it does, how to reuse something you already own, and which partner pick fills the gap if you need to buy.

Reuse yours / Partner pick

Furniture

Your Furniture Shell

Any window-side bench, sideboard or cabinet becomes the body of the system — yours, in your style.

Open part
Reuse yours / Partner pick

Furniture

Public Ceiling PCM Field

The existing suspended ceiling, rails and access zones that host the PCM modules in a public building.

Open part
We ship

Thermal storage

PCM Module Bank

T3 high-conductivity PCM modules — the core product we make and ship.

Open part
Reuse yours / Partner pick

Cooling

Night Air Path

Your window is the charger. A simple grille or duct guide steers night air through the PCM.

Open part
Reuse yours / Partner pick

Cooling

Airflow Fan

Any quiet 120–140 mm PWM or USB fan you own — or a partner pick if you need one.

Open part
Reuse yours / Partner pick

Cooling

Ceiling Air Distribution

Existing AHU / fan-coil circulation or a dedicated low-pressure plenum loop moves room air across the ceiling PCM field.

Open part
Online model · no hardware

Control

Studio AI Calculation Model

The online model used on this page to size PCM, simulate room temperature and prepare operating guidance.

Open part
Reuse yours / Partner pick

Recharge

Hybrid Recharge

Hot nights? Your existing AC or portable cooler tops up the PCM off-peak — no new machine required.

Open part
Reuse yours / Partner pick

Retrofit

Solar Shading

Your curtains, blinds or an awning — the cheapest cooling you will ever install.

Open part
Reuse yours / Partner pick

Control

Monitoring Kit

Optional loggers that verify what your build really delivers — comfort hours, recharge %, noise.

Open part

Future options

Thermal performance comes first.

Future comfort modules may include air filtration and indoor wellness options. The first release focuses on thermal performance and project-specific validation — modules designed to disappear into furniture you are proud of, from window benches to sideboards.

Walnut slatted sideboard with brass legs in a bright room — furniture ready to host a PCM module bank